what cap to add to stop tremolo ticking SF fender

General discussion area for tube amps.

Moderators: pompeiisneaks, Colossal

Post Reply
User avatar
sidehatch
Posts: 167
Joined: Mon Jun 16, 2008 4:42 pm

what cap to add to stop tremolo ticking SF fender

Post by sidehatch »

I used to know but cant remember. I used to have a photo saved on where to add it.

Can anyone refresh my memonry?

thanks
User avatar
Structo
Posts: 15446
Joined: Wed Oct 17, 2007 1:01 am
Location: Oregon

Re: what cap to add to stop tremolo ticking SF fender

Post by Structo »

Which amp?
Tom

Don't let that smoke out!
User avatar
sidehatch
Posts: 167
Joined: Mon Jun 16, 2008 4:42 pm

Re: what cap to add to stop tremolo ticking SF fender

Post by sidehatch »

This one is an early 70's pro reverb.

Is it a .01 cap in parallel with the 10 meg resister?
funkmeblue
Posts: 485
Joined: Mon Mar 13, 2006 4:17 am
Location: akron, ohio

Re: what cap to add to stop tremolo ticking SF fender

Post by funkmeblue »

.022uf 400 volt across the 10 meg according to gerald weber
anything worth doing, is worth doing right
User avatar
Richie
Posts: 1175
Joined: Mon Jan 09, 2006 3:44 am
Location: Ky

Re: what cap to add to stop tremolo ticking SF fender

Post by Richie »

the cap across the 10M was an older fender service bulletin.
the newer one lists a .01 600v mylar cap from the 10M where it connects to the bug.. amd the other end of cap to ground. If this still doesn't cure the tick it also suggest the lead dress to the tube..bunch them together..

also the leads to the intensity and speed..keep them away from the tone controls,and filter leads..

this is from the fender sevice manual.. bulletin #9