I'm having trouble figuring out a good component rating for split-load (aka Fast/Gradual) switch. Since we're dealing with the B+ here, I figure you don't want use any old switch. Can anyone make a recommendation here? Thanks.
User avatar
Noel Grassy
Posts: 426
Joined: Thu Feb 09, 2006 5:29 am
Location: Vacuum Tube Valley-Cali

Re: Split Load Switch

Post by Noel Grassy »

Tim, It looks like most folks use the mini toggles w/ 6A @125VAC rating.
I swung with Mouser's pt#690-123S1YZQ. IMO the Mountain Switch brand is garbage. But Alcoswitch, C&K, or NKK will give you a decent product for the money. I don't know what the actual current is at that position. I bet Skyboltone is furrowing his brow at such negligence. Maybe a more skilled individual will school us both. :)
All excellent things are as difficult as they are rare__B Spinoza
Tim Hall
Posts: 9
Joined: Mon Apr 30, 2007 12:05 am

Re: Split Load Switch

Post by Tim Hall »

Actually I think I must have had a little brain fart on this one. I guess I'd really only be switching the signal off the plate, and not the B+ over the R. Is that right? If so, I could use a tiny switch.
User avatar
Richie
Posts: 1175
Joined: Mon Jan 09, 2006 3:44 am
Location: Ky

Re: Split Load Switch

Post by Richie »

you might ask Allyn or Ur12.. they have a fast gradulal switching board,so you can make it quiet footswitchable. If you use a manual switch,you'd have to set it to the position you wanted,or there would be a pop or thump sound when switched. Unless you used a different method,or modded the circut.
About any switch should work for that. Not much voltage or current in that section. Most switches are rated AC..so those would be about double rated for DC voltage.
User avatar
Allynmey
Site Admin
Posts: 1406
Joined: Sun Mar 06, 2005 12:38 am
Location: Dighton, MA

Re: Split Load Switch

Post by Allynmey »

you could run a cap off both spots to the switch and have the center connector go to the next stage. You will need 1M ground reference resistors on the switch to get rid of the pop.
User avatar
billyz
Posts: 1305
Joined: Fri Aug 10, 2007 6:17 pm
Location: Spokane, WA
Contact:

Re: Split Load Switch

Post by billyz »

Allyn,

Where do you attach the 1 m resistor to ground? I mean not the grounded side the switch side.

Thanks
User avatar
Allynmey
Site Admin
Posts: 1406
Joined: Sun Mar 06, 2005 12:38 am
Location: Dighton, MA

Re: Split Load Switch

Post by Allynmey »

at the switch after the cap
Tim Hall
Posts: 9
Joined: Mon Apr 30, 2007 12:05 am

Re: Split Load Switch

Post by Tim Hall »

Cool. Thanks for the replies.
User avatar
bnwitt
Posts: 379
Joined: Sat Feb 25, 2006 7:51 pm

Re: Split Load Switch

Post by bnwitt »

What value caps? 0.1uf? should one eliminate the cap downstream then?
You do not have the required permissions to view the files attached to this post.
Great things happen in a vacuum
User avatar
Allynmey
Site Admin
Posts: 1406
Joined: Sun Mar 06, 2005 12:38 am
Location: Dighton, MA

Re: Split Load Switch

Post by Allynmey »

Yup! :D
User avatar
bnwitt
Posts: 379
Joined: Sat Feb 25, 2006 7:51 pm

Re: Split Load Switch

Post by bnwitt »

Well with that setup one might as well put in a relay and make it foot switchable.
Great things happen in a vacuum
User avatar
billyz
Posts: 1305
Joined: Fri Aug 10, 2007 6:17 pm
Location: Spokane, WA
Contact:

Re: Split Load Switch

Post by billyz »

Since you guys are showing a .1uf coupling cap, am I to assume you are switching V2A and not V1A ? I have been using the V1A and really like the results, so much that I never got around to trying V2A. Also, when I grounded the 1 meg resistor after the cap (.002) I did pickup some hum. Possibly a ground loop.
nee
Posts: 89
Joined: Sun Jun 29, 2008 3:39 am

Re: Split Load Switch

Post by nee »

I've been playing around with the split load switch on V2a.

First of all I had the center lug of the switch connected to the .1uf cap, but there was a thump through the speakers when the switch was thrown, and I didn't like the idea of the B+ being on a front panel switch anyway.

So I did as Allynmey suggested above and used 2 x .1uf before the switch, rather than 1 after. While there was now no DC on the switch, there was still a speaker thump on switching, so I again did as Allynmey suggested and added a 1M resistor to ground from switch side of each cap to ground.

I'm certain everything is wired correctly, but with this configuration I get no signal at all. It's as if the entire signal is being shunted to ground.
IanG
User avatar
M Fowler
Posts: 14036
Joined: Wed Jan 16, 2008 2:19 am
Location: Walcott ND

Re: Split Load Switch

Post by M Fowler »

Yeah my switch pops when engaging the gain, I left it that way.

Preamp gain center pin on switch to .1 uf/600v
Hard top of switch to junction of 82k/22k
soft bottom of switch to junction of pin 6/82k