Anodized Liverpool chassis
Moderators: pompeiisneaks, Colossal
Anodized Liverpool chassis
I've anodized the chassis I got with my Ceriatone Liverpool kit which will act as an electrical insulator. Other than the star grounds and connection to the bottom plate in the cab, will I need to remove the anodizing from any other connection points? Ex. tube sockets, board stand-offs etc...
-
leaveitalone84
- Posts: 185
- Joined: Thu Nov 15, 2007 6:29 pm
- Location: Boston, MA
Re: Anodized Liverpool chassis
Board standoffs should be fine as they are not electrical connections only mechanical.
But I would remove material around the screw holes for the jacks, pots and tube socket screws.
But I would remove material around the screw holes for the jacks, pots and tube socket screws.
Re: Anodized Liverpool chassis
I'd go farther and tap the ground holes instead of thru-drilling. Kep-nuts do a good job scrapping the surface.