Post by bieworm »

i edited the previous post
bieworm
Posts: 46
Joined: Tue Dec 30, 2014 7:14 am
Location: belgium Europe

Re: Grounding questions on tube reverb unit

Post by bieworm »

Ok did all of that. Even built a new rectifier to rule that out too. Replaced the tranny with a toroidal one.
Hum reduced a little... but not much. Then I tried some caps across the sec winding , just before the rectifier. With a .68uf cap the hum was nearly gone. But it also meant that there was a loss of treble in the reverb...
Is there actually any harm in putting that cap there? It's 630V rated. And the voltage across those wires is 240VAC.
TUBEDUDE
Posts: 1864
Joined: Thu Jan 04, 2007 5:23 pm
Location: Mastersville

Re: Grounding questions on tube reverb unit

Post by TUBEDUDE »

problem want an X class cap of higher voltage rating.
Tube junkie that aspires to become a tri-state bidirectional buss driver.
bieworm
Posts: 46
Joined: Tue Dec 30, 2014 7:14 am
Location: belgium Europe

Re: Grounding questions on tube reverb unit

Post by bieworm »

TUBEDUDE wrote: Mon Jul 27, 2020 8:55 pm problem want an X class cap of higher voltage rating.
I ordered some stuff to try out other options:

- 3kV ceramic cap for replacement of that .68uf
- 2kV .02uf ceramic caps to connect parallel to the rectifier diodes
- 150uf electrolytic filter caps to replace the 100uf's
- a 6BX6 power tube to replace that 6AU6... I will have to replace the 7 pin socket too for that
- some new and different 12ax7 tubes