Did I get this right, I wonder?

Overdrive Special, Steel String Singer, Dumbleland, Odyssey, Winterland, etc. -
Members Only

Moderators: pompeiisneaks, Colossal

Post Reply
Oddvar R
Posts: 493
Joined: Tue Jan 09, 2018 7:39 am

Did I get this right, I wonder?

Post by Oddvar R »

Hi. I was hoping someone could look at this board and check if I got it right? Compared to the layout? It's the placement of the 22m resistors, that says"22M from NC to Com on both contacts." Sorry, but relays get the better of me, or worse.
You do not have the required permissions to view the files attached to this post.
sluckey
Posts: 3528
Joined: Sun Jul 22, 2007 7:48 pm
Location: Mobile, AL
Contact:

Re: Did I get this right, I wonder?

Post by sluckey »

Wrong.
User avatar
pompeiisneaks
Site Admin
Posts: 4244
Joined: Sat Jan 14, 2017 4:36 pm
Location: Washington State, USA
Contact:

Re: Did I get this right, I wonder?

Post by pompeiisneaks »

wrong, the first two posts are for the relay 5v contacts to enable the switch. The two you need are to go from pins 2 to 3 on either side. Part of what makes this confusing as well is that you've got a hoffman relay (I used them on my build too) but you're looking at the dumble style relays that send all the pins over to the one side.

~Phil
tUber Nerd!
Oddvar R
Posts: 493
Joined: Tue Jan 09, 2018 7:39 am

Re: Did I get this right, I wonder?

Post by Oddvar R »

Thank you, it's a bit confusing this, I have at least three different layouts, but then again, relays are not my usual cup of tea...
User avatar
pompeiisneaks
Site Admin
Posts: 4244
Joined: Sat Jan 14, 2017 4:36 pm
Location: Washington State, USA
Contact:

Re: Did I get this right, I wonder?

Post by pompeiisneaks »

Yeah it's a mental mapping exercise.

The first two pins top and bottom on the left on yours compare to the top and bottom leftmost pins in the layout to the LEFT of the diode. That's the relay power on/off for the coil

Then the pinout on the dumble is labelled by me as "Top and Bottom" pins 1,2,3 (T1,T2,T3,B1,B2,B3) relate like so:

T1,B1,T2,B2,T3,B3

which they've written as

(Com=common, NC=Normally Connected, NO=Normally Open)
Com1,Com2,NC1,NC2,NO1,NO2

on the layout.

Does that help?

See Picture:
Relay 2.jpg
~Phil
You do not have the required permissions to view the files attached to this post.
tUber Nerd!
Oddvar R
Posts: 493
Joined: Tue Jan 09, 2018 7:39 am

Re: Did I get this right, I wonder?

Post by Oddvar R »

Thanks a lot, that's very clear. I am also wondering where the two voltage leads from the 12v transformer is coming inn. Some say only one goes in, others indicate two on each side of the diode, others has one coming from the main board?
Last edited by Oddvar R on Sat Mar 09, 2019 10:43 am, edited 1 time in total.
User avatar
norburybrook
Posts: 3290
Joined: Mon Jan 06, 2014 12:47 am
Location: London
Contact:

Re: Did I get this right, I wonder?

Post by norburybrook »

Oddvar R wrote: Sat Mar 09, 2019 10:24 am Thanks a lot, that's very clear. I am also wondering where the two voltage leads from the 12v transformer is coming inn. Some says only one goes in, others indicate two on each side of the diode, others has one coming from the main board?
the rectified voltage comes from the rectifier board and then to the regulator input then to the output where it's now 12v and into the striped end of the diode on the board, the other end goes to the switch on the rear, which goes to the footswitch as well.



M
User avatar
pompeiisneaks
Site Admin
Posts: 4244
Joined: Sat Jan 14, 2017 4:36 pm
Location: Washington State, USA
Contact:

Re: Did I get this right, I wonder?

Post by pompeiisneaks »

Yup exactly as Marcus says, you send in 12v to the + side and the rest goes off to the switches to 'complete' the circuit for the relay coil.

Edit: to clarify that's the red + and the black - on the left side of my picture, the 12V + and -. (minus goes off to the switches which either provide it reference to ground to 'activate' the relay, or open to block reference to ground keeping the relay at it's unpowered setting.

~Phil
tUber Nerd!
Oddvar R
Posts: 493
Joined: Tue Jan 09, 2018 7:39 am

Re: Did I get this right, I wonder?

Post by Oddvar R »

Thanks guys, much appreciated. I am using, for some reason, two layouts at once, they differ a bit in the lead connections, so I am trying to get it as right as possible the first time.
amplifiednation
Posts: 2091
Joined: Sun Dec 26, 2010 6:19 pm
Location: Boston
Contact:

Re: Did I get this right, I wonder?

Post by amplifiednation »

The relay works the same as a regular DPDT toggle switch. One pair of contacts is connected when off, and when engaged it switches to the other set of contacts.
Amplified Nation
www.amplifiednation.com
@ampnation