Fuse protection

General discussion area for tube amps.

Moderators: pompeiisneaks, Colossal

Post Reply
User avatar
RWood
Posts: 254
Joined: Sun Jul 07, 2013 7:56 pm

Fuse protection

Post by RWood »

I found Keen's articles about fuse protecting B+ and PT supplies but having trouble finding info as to type and sourcing. Anyone using these methods of protection? I'd hate to loose a good PT or rectifier because of plate shorts (which I experienced recently when installing a new 6L6 which had shorted plates), or filter cap failure.
Thanks in advance...Randy
User avatar
David Root
Posts: 3540
Joined: Fri Aug 04, 2006 3:00 pm
Location: Chilliwack BC

Re: Fuse protection

Post by David Root »

I only use OT B+ fuses on valuable vintage iron. Fast blow, maybe 500mA on a 50W and 800-1000mA on 100W.

HT winding fuse on a PT-again if it's vintage iron.

In a vintage amp you can use the ground switch hole for an OT fuse, otherwise it's internal. In a new build of course anywhere you want.
pdf64
Posts: 2932
Joined: Sat Mar 12, 2011 9:23 pm
Location: Staffordshire, UK
Contact:

Re: Fuse protection

Post by pdf64 »

See Merlin's thoughts on the topic http://www.valvewizard.co.uk/fuses.html
https://www.justgiving.com/page/5-in-5-for-charlie This is my step son and his family. He is running 5 marathons in 5 days to support the research into STXBP1, the genetic condition my grandson Charlie has. Please consider supporting him!
tubeswell
Posts: 2337
Joined: Thu Mar 27, 2008 6:42 am
Location: Wellington. NZ

Re: Fuse protection

Post by tubeswell »

As a RoT, use 250mA T fuse for each pair of EL84 or 6V6s, 500mA T fuse for each pair of EL34s or 6L6s. (You want it to be about 2 x the max current draw you'd expect more or less). YMMV
He who dies with the most tubes... wins