Trouble shooting HRD

General discussion area for tube amps.

Moderators: pompeiisneaks, Colossal

Post Reply
Hoot
Posts: 2
Joined: Sat Feb 08, 2014 12:46 am

Trouble shooting HRD

Post by Hoot »

HRD had crackle and pop while on. Pulled the back. Changing tubes and had a spark from R61. Need to replace this one first. Spec says 1watt, 470 ohms. Question is is this a metal foil or carbon type? Best place to find replacement?
User avatar
Reeltarded
Posts: 10189
Joined: Sat Feb 14, 2009 4:38 am
Location: GA USA

Re: Trouble shooting HRD

Post by Reeltarded »

Changing tubes and it sparked? How?
Signatures have a 255 character limit that I could abuse, but I am not Cecil B. DeMille.
User avatar
xtian
Posts: 7263
Joined: Mon Apr 19, 2010 8:15 pm
Location: Chico, CA
Contact:

Re: Trouble shooting HRD

Post by xtian »

Metal foil. I don't think there are any carbon comp resistors in a modern HRD.
I build and repair tube amps. http://amps.monkeymatic.com
jestaudio
Posts: 654
Joined: Sat Mar 12, 2011 4:12 pm
Location: UK

Re: Trouble shooting HRD

Post by jestaudio »

while your at it reflow the joints on the power tube sockets, known to dry joint on a regular basis
Hoot
Posts: 2
Joined: Sat Feb 08, 2014 12:46 am

For reeltarded

Post by Hoot »

I was cleaning the tube sockets working on the crackle problem. Put the GT whites back in and turned on the amp. Spark came out of R61. Blew a hole in it! Planning on fixing R61 and replacing the power tubes as one was running very hot.