Post by wsaraceni »

i only get to do this once, so i want to do it right.


im using a set of toneslut trainwreck transformers that i have a laydown endbell on the power transformer. since everything comes out the middle, i'm a little unsure which direction it mounts. there is a copper strip on the shorter two sides and the longer two sides are plain. do the longer sides go front to back or parallel to the front and rear?

A.

[img:2403:1802]http://img.photobucket.com/albums/v217/ ... 178e3d.jpg[/img]

or B.

[img:2506:1880]http://img.photobucket.com/albums/v217/ ... 3cc43c.jpg[/img]
printer2
Posts: 146
Joined: Sat Jun 26, 2010 5:14 am
Location: Canada

Re: laydown transformer orientation

Post by printer2 »

No idea which way it should go. But what you could do is hool up some headphones to the OT secondary and put power to your PT. Try the transformers in different orientations to get the lowest hum. Don't forget to tape off the unused leads.
User avatar
M Fowler
Posts: 14036
Joined: Wed Jan 16, 2008 2:19 am
Location: Walcott ND

Re: laydown transformer orientation

Post by M Fowler »

Doesn't matter just pick one way or the other.
tubeswell
Posts: 2337
Joined: Thu Mar 27, 2008 6:42 am
Location: Wellington. NZ

Re: laydown transformer orientation

Post by tubeswell »

wsaraceni wrote:i only get to do this once, so i want to do it right.
There is no 'once' in tube amp building.

Otherwise - what Mark said.
He who dies with the most tubes... wins
User avatar
martin manning
Posts: 14308
Joined: Sun Jul 06, 2008 12:43 am
Location: 39°06' N 84°30' W

Re: laydown transformer orientation

Post by martin manning »

I like B, but I would recommend confirming that by energizing the PT and measuring the induced voltage on the OT secondary. You can set the PT up on some blocks and similarly the OT to bring it up to the level it will be when they are both mounted to the chassis. You can rotate the OT to see which way is best.
User avatar
JazzGuitarGimp
Posts: 2357
Joined: Mon Jul 23, 2012 4:54 pm
Location: Northern CA

Re: laydown transformer orientation

Post by JazzGuitarGimp »

I would have said exactly what Martin said.
Lou Rossi Designs
Printed Circuit Design & Layout,
and Schematic Capture
User avatar
xtian
Posts: 7263
Joined: Mon Apr 19, 2010 8:15 pm
Location: Chico, CA
Contact:

Re: laydown transformer orientation

Post by xtian »

And I say exactly what Martin says, after he says it.
I build and repair tube amps. http://amps.monkeymatic.com
User avatar
David Root
Posts: 3540
Joined: Fri Aug 04, 2006 3:00 pm
Location: Chilliwack BC

Re: laydown transformer orientation

Post by David Root »

I think B is how Leo did it. Good enuff for me.