We're all nuts, so join the crowd. Texas pecans mm now that's good!Blackburn wrote:There's kind of a harshness in that amp. A kind of tone that's thin and papery that I feel may be due to the Xicons I have in there. Maybe I'm nuts?
Seriously now, have you looked at the output with a scope? Harsh, thin, papery, all describe what we hear when parasitic (ultrasonic) oscillations are present. Gotta scope it while driving speaker(s) as resistor loading doesn't often show this problem. I seriously doubt Xicon film caps are to blame.
Also doesn't hurt to have a cap meter in the workshop. Good investment, figure on $50-100. Some multimeters now include one.