sound city 50R problem
Moderators: pompeiisneaks, Colossal
- chief mushroom cloud
- Posts: 429
- Joined: Tue Jan 18, 2005 5:42 pm
- Location: Peenemunde CA
sound city 50R problem
ok, all you brainiacs....I have a challenge:
I have a SC 50R on the bench.
Everything works dandy...EXCEPT...
there is 6Vp-p 120Hz ripple on the HT caps when standby is switched on. Textbook ripple. Real purty. This translates to over 4p-p on the OT secondaries. Loud.
Amp puts out healthy 50W clean (just before clipping).
Amp draws 105mA at idle.
I disengaged the preamp HT from power and screen HT. Ripple is still there. Unsoldered all the OT connections and measured DCR w/ DMM. Looks good, but I also know that doesn't tell the whole story.
Checked windings ratio (per Jelle's suggestion) and looks good...nice 3.4k OT.
I've isolated the EL34s from incoming coupling caps. Ripple still there.
I've moved wires around (and chopsticked)...absolutely no change in ripple.
When I shut off standby (disengages all circuitry from rectified HT)...HT goes flat, very nice ripple free 495V).
Now, I can only surmise that for whatever reason, there is a massive DC loading issue with the OT...and it's not able to cancel it out. But the idle draw doesn't raise a red flag here. But now I'm suspecting PT.
EL34s biased at 70% plate dissipation
Before I go out and buy another PT or OT (at my expense) and tack in for test...I need to know if I've missed anything.
Is there any good way to test PT in situ?
TIA
'as built' schematic attached
I have a SC 50R on the bench.
Everything works dandy...EXCEPT...
there is 6Vp-p 120Hz ripple on the HT caps when standby is switched on. Textbook ripple. Real purty. This translates to over 4p-p on the OT secondaries. Loud.
Amp puts out healthy 50W clean (just before clipping).
Amp draws 105mA at idle.
I disengaged the preamp HT from power and screen HT. Ripple is still there. Unsoldered all the OT connections and measured DCR w/ DMM. Looks good, but I also know that doesn't tell the whole story.
Checked windings ratio (per Jelle's suggestion) and looks good...nice 3.4k OT.
I've isolated the EL34s from incoming coupling caps. Ripple still there.
I've moved wires around (and chopsticked)...absolutely no change in ripple.
When I shut off standby (disengages all circuitry from rectified HT)...HT goes flat, very nice ripple free 495V).
Now, I can only surmise that for whatever reason, there is a massive DC loading issue with the OT...and it's not able to cancel it out. But the idle draw doesn't raise a red flag here. But now I'm suspecting PT.
EL34s biased at 70% plate dissipation
Before I go out and buy another PT or OT (at my expense) and tack in for test...I need to know if I've missed anything.
Is there any good way to test PT in situ?
TIA
'as built' schematic attached
You do not have the required permissions to view the files attached to this post.
Don't overthink it. Just drink it.
- martin manning
- Posts: 14308
- Joined: Sun Jul 06, 2008 12:43 am
- Location: 39°06' N 84°30' W
Re: sound city 50R problem
What about the 2x 200uF reservoir caps? With no load the plate supply node might look ok, but not so much when the standby is on and there is current draw.
- JazzGuitarGimp
- Posts: 2357
- Joined: Mon Jul 23, 2012 4:54 pm
- Location: Northern CA
Re: sound city 50R problem
My guess would be one of two things, or perhaps a bit of both:
- undersized PT
- under filtered
Another possibility might be somehing pulling heavy curent in the heater circuit, robbing power from the HT winding.
- undersized PT
- under filtered
Another possibility might be somehing pulling heavy curent in the heater circuit, robbing power from the HT winding.
Lou Rossi Designs
Printed Circuit Design & Layout,
and Schematic Capture
Printed Circuit Design & Layout,
and Schematic Capture
- chief mushroom cloud
- Posts: 429
- Joined: Tue Jan 18, 2005 5:42 pm
- Location: Peenemunde CA
Re: sound city 50R problem
well, I thought of that...BUT..these are brand spankin new F&Ts, and I tried brand spankin new ARS cap, too. Same prob.martin manning wrote:What about the 2x 200uF reservoir caps? With no load the plate supply node might look ok, but not so much when the standby is on and there is current draw.
I have a 100W Burman that uses the same power supply topology w/ two 200uF caps in same config....that amp is dead quiet.
but yea, no load...it's flat...w/ load it's overkill ripple. The 100W Burman has about .25V ripple w/ same caps.
Don't overthink it. Just drink it.
- chief mushroom cloud
- Posts: 429
- Joined: Tue Jan 18, 2005 5:42 pm
- Location: Peenemunde CA
Re: sound city 50R problem
Stock Partidge trannies and same filter as 100W Burman.JazzGuitarGimp wrote:My guess would be one of two things, or perhaps a bit of both:
- undersized PT
- under filtered
Another possibility might be somehing pulling heavy curent in the heater circuit, robbing power from the HT winding.
I will check the heaters now.....
Don't overthink it. Just drink it.
Re: sound city 50R problem
What about the bias cap?
- chief mushroom cloud
- Posts: 429
- Joined: Tue Jan 18, 2005 5:42 pm
- Location: Peenemunde CA
Re: sound city 50R problem
entire bias circuit new and rock steady...besides, it's a half wave rectifier, so it generates 60Hz ripple.....this is 120HzM Fowler wrote:What about the bias cap?
but keep the ideas coming...I appreciate ANY response at this point
Don't overthink it. Just drink it.
Re: sound city 50R problem
Morning all,
with the EL34s disconnected from the coupling caps - then surely any AC still lurking there could be from the filaments / heater circuit?
But why then does it measure no ripple with standby off, circuit disconnected from HT?
Got me running in circles, I need a huge coffee. I was asking myself if you have heavy rectifier pulse getting into the heater CT. Maybe elevate the heaters as a quick test. Saw something similar with a GA40 where the filament winding was funky. Separate filament iron was a simple fix and the original PT carries on without the heavy lifting.
Curious, is the PI filter grounded to the chassis as drawn?
Best, tony
with the EL34s disconnected from the coupling caps - then surely any AC still lurking there could be from the filaments / heater circuit?
But why then does it measure no ripple with standby off, circuit disconnected from HT?
Got me running in circles, I need a huge coffee. I was asking myself if you have heavy rectifier pulse getting into the heater CT. Maybe elevate the heaters as a quick test. Saw something similar with a GA40 where the filament winding was funky. Separate filament iron was a simple fix and the original PT carries on without the heavy lifting.
Curious, is the PI filter grounded to the chassis as drawn?
Best, tony
- martin manning
- Posts: 14308
- Joined: Sun Jul 06, 2008 12:43 am
- Location: 39°06' N 84°30' W
Re: sound city 50R problem
I'm leaning toward an OT problem. 6V p-p is not much ripple on 500V... 1.2%, and in theory the OT should be canceling it. But 4V p-p shoes up on the secondary? That doesn't sound right at all
Re: sound city 50R problem
Maybe it needs a choke .
Re: sound city 50R problem
measure the secondaries with dummy loads connected across each winding?chief mushroom cloud wrote:Is there any good way to test PT in situ
He who dies with the most tubes... wins
- martin manning
- Posts: 14308
- Joined: Sun Jul 06, 2008 12:43 am
- Location: 39°06' N 84°30' W
Re: sound city 50R problem
Nope. No blown fusees and 120Hz ripple says they are working.tubeswell wrote:Rectifier diode?
Chief, you could sub in any working OT (like a 4k Zpri Fender-type) to see if that is the problem.
Re: sound city 50R problem
Have you disconnected the NFB to rule that route out?
If it says "Vintage" on it, -it isn't.
- chief mushroom cloud
- Posts: 429
- Joined: Tue Jan 18, 2005 5:42 pm
- Location: Peenemunde CA
Re: sound city 50R problem
I think you're right. I've been in contact w/ Mark Huss, and he suggested the same thing. I have an A470 OT I'm going to tack in...if the ripple get's cancelled...the Partridge OT get's a rewind.martin manning wrote:Nope. No blown fusees and 120Hz ripple says they are working.tubeswell wrote:Rectifier diode?
Chief, you could sub in any working OT (like a 4k Zpri Fender-type) to see if that is the problem.
I suspected this at first, but had to eliminate everything else and the OT behaves and measures normally except for this. I forgot I had the A470 (and I actually have another 3.4k Partridge that I forgot about, but it's the size of a 100watter!)
stay tuned
Don't overthink it. Just drink it.