Mesa DC-3 Low Volume on Rhythm Channel

General discussion area for tube amps.

Moderators: pompeiisneaks, Colossal

Post Reply
User avatar
dorrisant
Posts: 2790
Joined: Tue Sep 21, 2010 1:27 pm
Location: Somewhere between a river and a cornfield
Contact:

Mesa DC-3 Low Volume on Rhythm Channel

Post by dorrisant »

I have tried a lot of things here.

All new known-good preamp tubes.
Cleaned tube sockets with Deoxit.
Reflowed solder joints at sockets.
Checked relays.
Checked LDRs.
Jumped out effects loop.
Footswitch functions properly.
EQ switches fine.
Lead channel seems fine.

Seems like the relays are not getting proper voltage. It acts like the LDRs are working.
Amp stethoscope gives good signal at the master volume pots.

Anyone have the Switching Matrix voltages?
Any ideas?

Thanks in advance.
Tony
"Education is what you're left with after you have forgotten what you have learned" - Enzo
User avatar
dorrisant
Posts: 2790
Joined: Tue Sep 21, 2010 1:27 pm
Location: Somewhere between a river and a cornfield
Contact:

Re: Mesa DC-3 Low Volume on Rhythm Channel

Post by dorrisant »

Figured it out...

It was one of the 4n33 optocouplers.

Changed all three while I was in there.

Next...
"Education is what you're left with after you have forgotten what you have learned" - Enzo