Adding a 9V reg supply to dumbleator...

General discussion area for tube amps.

Moderators: pompeiisneaks, Colossal

surfsup
Posts: 1513
Joined: Mon Nov 29, 2010 12:21 am
Location: Chicagoland

Adding a 9V reg supply to dumbleator...

Post by surfsup »

Has anyone used this tranny from triad? I am thinking it might work for a pedalbaord supply. Seems to put out enough to run several low draw pedals and a couple high draw like loop stations or delay boards (3.6A):

http://system.netsuite.com/core/media/m ... c&_xt=.pdf

(attached in case link doesn't work).
You do not have the required permissions to view the files attached to this post.
Last edited by surfsup on Sat Jun 30, 2012 6:21 pm, edited 2 times in total.
Jana
Posts: 1314
Joined: Sun Sep 07, 2008 10:40 pm
Location: Minnesota

Re: Adding a 9V reg supply to dumbleator...

Post by Jana »

I haven't used that one specifically but I have used that series before. They have never given me any problems.
surfsup
Posts: 1513
Joined: Mon Nov 29, 2010 12:21 am
Location: Chicagoland

Re: Adding a 9V reg supply to dumbleator...

Post by surfsup »

Okay so I decided to just add a 9v plug to my dumbleator since the Clator chassis is huge and there's plenty of room.

I figure why not just add another small tranny and some stuff to plug my delay/verb stuff right into the buffered loop with a short cord so they can sit on top of the amp and make cord life easier.

Here's what I think I will do...instead of a FWB off a 12.6VAC tranny, do an 18VCT with a capacitive bridge recto. I figure the bridge will deliver a bit more current and rectified it is 12.6VDC, about perfect for the regulator. Comments?

[img:692:337]http://chicagocadcam.com/ChrisHahn/Dumm ... ly3A_2.jpg[/img]
Bob S
Posts: 1575
Joined: Sat Feb 14, 2009 2:38 pm
Location: Up there with the Michiganders

Re: Adding a 9V reg supply to dumbleator...

Post by Bob S »

Should be fine for up to 2A with decent heat sinking.
Good idea to add one to a dumbleator.
Why Aye Man
surfsup
Posts: 1513
Joined: Mon Nov 29, 2010 12:21 am
Location: Chicagoland

Re: Adding a 9V reg supply to dumbleator...

Post by surfsup »

Yea, was surprised after googling this site there were no references or gutshots. I finally can claim a first! 8)
Bob S
Posts: 1575
Joined: Sat Feb 14, 2009 2:38 pm
Location: Up there with the Michiganders

Re: Adding a 9V reg supply to dumbleator...

Post by Bob S »

I'd like permission to clone this please.
:lol:
Great Idea!
Why Aye Man
surfsup
Posts: 1513
Joined: Mon Nov 29, 2010 12:21 am
Location: Chicagoland

Re: Adding a 9V reg supply to dumbleator...

Post by surfsup »

Go for it. I am putting it in a Clator chassis so the trannys will be swimming in space...I am debating actually doing two separate supplies. Working on the layout now if I can get all three trannies and parts in there I'm going to put in one 9v and maybe a 12v or another 9v.

I'm looking at this tranny for the 9v tap(s): Xicon 41FJ300 at mouser. $6
Jana
Posts: 1314
Joined: Sun Sep 07, 2008 10:40 pm
Location: Minnesota

Re: Adding a 9V reg supply to dumbleator...

Post by Jana »

Is the ground of this circuit going to be tied to the amp chassis/ground? If so, will there be issues with ground loops? I built a 9 volt supply into an amp once but the 9v was isolated from the amp chassis.
Bob S
Posts: 1575
Joined: Sat Feb 14, 2009 2:38 pm
Location: Up there with the Michiganders

Re: Adding a 9V reg supply to dumbleator...

Post by Bob S »

Could be an issue Jana - good catch.
I like bridge rectifiers for dc. Maybe a 9 volt transformer / bridge rectifier, floating the 9 volt dc supply.
Why Aye Man
User avatar
Super_Reverb
Posts: 188
Joined: Tue Dec 21, 2010 6:28 am
Location: Indianapolis, USA

Re: Adding a 9V reg supply to dumbleator...

Post by Super_Reverb »

The 9V output is already floating, no? 9V supply output from regulator has CT ground reference. These two terminals look like a 9V battery.

If you use this to power effects pedals, wont the (-) side of 9V supply be grounded through the patch cable ground?


rob
surfsup
Posts: 1513
Joined: Mon Nov 29, 2010 12:21 am
Location: Chicagoland

Re: Adding a 9V reg supply to dumbleator...

Post by surfsup »

I like bridge rectifiers for dc. Maybe a 9 volt transformer / bridge rectifier, floating the 9 volt dc supply.
Why do you like bridge rectos? They deliver less current (though the tranny will be physically smaller usually).

Also, If I recall (being the next day I was looking at trannies), Mouser had only like one 9V tranny and it was a 60mA one. So I started looking at others and settled on the 18 VCT one.

18V should give me approx 12.6vdc after rectification with a full wave

Xicon Transformer:
Primary Voltage: 115VAC, 60Hz
Primary Exciting Current: 40mA (max.)
Secondary Voltage (no load): 20.6CT VAC±0.6V%
Secondary Voltage (full load): 18.0CT VAC±0.6V%
Rated Secondary Current: 0.3 Amp (AC) @ 60Hz
Last edited by surfsup on Mon Jul 02, 2012 8:37 pm, edited 1 time in total.
surfsup
Posts: 1513
Joined: Mon Nov 29, 2010 12:21 am
Location: Chicagoland

Re: Adding a 9V reg supply to dumbleator...

Post by surfsup »

For the ground, if i use a CT, do I have to ground at the chassis or can I run it to the jack ground as in this:

[img:640:479]http://www.geofex.com/Article_Folders/S ... pyder6.gif[/img]
Bob S
Posts: 1575
Joined: Sat Feb 14, 2009 2:38 pm
Location: Up there with the Michiganders

Re: Adding a 9V reg supply to dumbleator...

Post by Bob S »

I should have said I like bridge rectification for low voltage dc.
Both full wave & bridge have advantages / disadvantages.
Still a great idea.
It will be a while before I can get to adding this, so I'll be interested in how it turns out.
Why Aye Man
User avatar
martin manning
Posts: 14308
Joined: Sun Jul 06, 2008 12:43 am
Location: 39°06' N 84°30' W

Re: Adding a 9V reg supply to dumbleator...

Post by martin manning »

surfsup wrote:For the ground, if i use a CT, do I have to ground at the chassis or can I run it to the jack ground as in this...
No problem, you can float the ground. It will eventually get referenced to the chassis through the patch cords.
surfsup
Posts: 1513
Joined: Mon Nov 29, 2010 12:21 am
Location: Chicagoland

Re: Adding a 9V reg supply to dumbleator...

Post by surfsup »

Martin thanks for confirming, bob I think i'm going to press forward with the 12.6vct tranny for this. I havent ordered the stuff yet though so it will still take me some time too.
Post Reply