artificial center tap grounding

Overdrive Special, Steel String Singer, Dumbleland, Odyssey, Winterland, etc. -
Members Only

Moderators: pompeiisneaks, Colossal

Post Reply
Ed de Jager
Posts: 186
Joined: Fri Jan 14, 2005 4:01 pm
Location: the Netherlands

artificial center tap grounding

Post by Ed de Jager »

Hi,i am wondering,since my PT doesn`t have a center tap for the heaters i am using 2 100Ohm resistors to ground.
What is the best way;use the groundbus on the pots or use another location like the PT or is there a better location?

Thanks very much in advance!

Ed
Normster
Posts: 1183
Joined: Tue Feb 07, 2006 12:26 pm
Location: Sacramento, CA
Contact:

Re: artificial center tap grounding

Post by Normster »

I don't know if it's the best way, but I've seen at least one Dumble photo with the 100R's grounded at a tab on the power tube mount screw.
You do not have the required permissions to view the files attached to this post.
Ed de Jager
Posts: 186
Joined: Fri Jan 14, 2005 4:01 pm
Location: the Netherlands

Re: artificial center tap grounding

Post by Ed de Jager »

Thanks Normster,i never saw that before but it actually seems a convenient way to mount them.
I thought about mounting them on a solder lug at one of the legs of the PT and i guess i have to make up my mind now.

Ed
groovtubin
Posts: 1114
Joined: Tue Feb 07, 2006 4:52 am

Re: artificial center tap grounding

Post by groovtubin »

Ed de Jager wrote:Thanks Normster,i never saw that before but it actually seems a convenient way to mount them.
I thought about mounting them on a solder lug at one of the legs of the PT and i guess i have to make up my mind now.

Ed
You do not have the required permissions to view the files attached to this post.
User avatar
Bob-I
Posts: 3791
Joined: Thu Feb 02, 2006 10:06 pm
Location: Hillsborough NJ

Re: artificial center tap grounding

Post by Bob-I »

Since I've been building a SLOClone I've been looking at some of the discussion on the SLOClone forum. Soldano uses straight 3/64" brass rod inserted through the socket pins for heaters on the 9 pin tubes. The power tubes have the wires running parallel in a straight line over the sockets. The connected between the 2 is twisted and the connection to the PT is twisted.

Many of the folks use a modified faks CT there. I've yet to try this so the jury's still out.

[img:874:474]http://i18.tinypic.com/29zy5gj.jpg[/img]

Note the the 2 100R resistors are connected to a 1M and 100K||47uF/100V. The 1M is in turn connected to the second node on the power supply. The 1M/100k is a voltage divider to lift the heater CT above ground by maybe 50V.

Interesting, I'll be trying it soon.

Here's the pics of my SLOClone so far for anyone interested..... click on the thumbnail to get to the webshots page.

[IMG:100:32]http://thumb9.webshots.net/t/59/559/9/12/73/2781912730033762409BqNZTH_th.jpg[/img]
User avatar
Bob-I
Posts: 3791
Joined: Thu Feb 02, 2006 10:06 pm
Location: Hillsborough NJ

Re: artificial center tap grounding

Post by Bob-I »

Here's some pics of a SLO where you can see the heater wiring closely.

[img:640:480]http://sloclone.yesterdaysrevolt.com/images/126.jpg[/img]

[img:640:480]http://sloclone.yesterdaysrevolt.com/images/125.jpg[/img]
User avatar
Funkalicousgroove
Posts: 2235
Joined: Mon Jul 25, 2005 8:04 pm
Location: Denver, CO
Contact:

Re: artificial center tap grounding

Post by Funkalicousgroove »

On a Dumble they are located on pin 7 of tube5 and pin 2 of tube 4.
Owner/Solder Jockey Bludotone Amp Works
groovtubin
Posts: 1114
Joined: Tue Feb 07, 2006 4:52 am

Re: artificial center tap grounding

Post by groovtubin »

Bob-I wrote:Here's some pics of a SLO where you can see the heater wiring closely.

[img:640:480]http://sloclone.yesterdaysrevolt.com/images/126.jpg[/img]

[img:640:480]http://sloclone.yesterdaysrevolt.com/images/125.jpg[/img]
Bob, i`ve seen a REAL early version of a SLO w/CARBON COMP screen grid resistors!!!! wish i still had that photo, it was cuhl!!
DaveBo32
Posts: 71
Joined: Sat Feb 24, 2007 3:44 am
Location: Salem, NH

Re: artificial center tap grounding

Post by DaveBo32 »

Normster,
The artificial CT only needs to be executed once? If I have a CT should I ground it or should I tie it off and use the 2 100ohms to ground? I heard it helps with eliminating hum more effectively. If I use the 2 100ohms to ground, do I only do this once not repeatedly?

Thanks,
Dave
User avatar
Bob-I
Posts: 3791
Joined: Thu Feb 02, 2006 10:06 pm
Location: Hillsborough NJ

Re: artificial center tap grounding

Post by Bob-I »

DaveBo32 wrote:Normster,
The artificial CT only needs to be executed once? If I have a CT should I ground it or should I tie it off and use the 2 100ohms to ground? I heard it helps with eliminating hum more effectively. If I use the 2 100ohms to ground, do I only do this once not repeatedly?

Thanks,
Dave
If you have a CT use it and skip the 100 ohm resistors.
DaveBo32
Posts: 71
Joined: Sat Feb 24, 2007 3:44 am
Location: Salem, NH

Re: artificial center tap grounding

Post by DaveBo32 »

Thanks Bob-I. I'm going to use the CT.
Post Reply