Help wiring impedence selector

Post by amplifiednation »

Hey guys, where does the ground connection go on this switch, and where do each of the impedance leads go? It's just a rotary switch, right, so each position is just one selection? And then I assume there is one common for ground, whch i probably the single terminal on the inside of the switch??

Any help would be great.

Thanks,
Taylor
You do not have the required permissions to view the files attached to this post.
Amplified Nation
www.amplifiednation.com
@ampnation
User avatar
M Fowler
Posts: 14036
Joined: Wed Jan 16, 2008 2:19 am
Location: Walcott ND

Re: Help wiring impedence selector

Post by M Fowler »

Good lord I hate those switches. The build guide has some info on wiring the switch. Ron Worley did a few posts for guys having trouble if you can search for that.

I used Hoffman's heavy duty switch instead.
You do not have the required permissions to view the files attached to this post.
User avatar
rdjones
Posts: 818
Joined: Tue Aug 31, 2010 2:20 am
Location: Music City, TN

Re: Help wiring impedence selector

Post by rdjones »

Unless this is for one of those complicated Hammond series/parallel secondary OTs, the ground is common and not connected to the switch.

rd
User avatar
angelodp
Posts: 2157
Joined: Tue Jan 15, 2008 2:45 am
Location: L.A.

Hope this helps

Post by angelodp »

amplifiednation
Posts: 2091
Joined: Sun Dec 26, 2010 6:19 pm
Location: Boston
Contact:

Re: Help wiring impedence selector

Post by amplifiednation »

OK...so have the layout and still feel like i'm doing this all wrong. my switch isn't not exactly like the one in the pic. does anyone know how these switches work?? i def do not. i think that would help me figure this out for good.
Amplified Nation
www.amplifiednation.com
@ampnation
User avatar
rdjones
Posts: 818
Joined: Tue Aug 31, 2010 2:20 am
Location: Music City, TN

Re: Help wiring impedence selector

Post by rdjones »

amplifiednation wrote:OK...so have the layout and still feel like i'm doing this all wrong. my switch isn't not exactly like the one in the pic. does anyone know how these switches work?? i def do not. i think that would help me figure this out for good.
When in doubt, Ohm it out.

rd
User avatar
martin manning
Posts: 14308
Joined: Sun Jul 06, 2008 12:43 am
Location: 39°06' N 84°30' W

Re: Help wiring impedence selector

Post by martin manning »

Looks like the layout is showing a 2-pole, 6-position switch, with 3 of the 6 in use and the two poles paralleled for redundancy. The wiring is like the attached. If you can find the manufacturer's data sheet that will clear things up, or you can use your DMM to discover which terminals are which. I believe that the two terminals that are 180 degrees apart and not in line with the spacing of the others are the commons, which you tie together and run to the speaker jack.
You do not have the required permissions to view the files attached to this post.
amplifiednation
Posts: 2091
Joined: Sun Dec 26, 2010 6:19 pm
Location: Boston
Contact:

Re: Help wiring impedence selector

Post by amplifiednation »

martin manning wrote:Looks like the layout is showing a 2-pole, 6-position switch, with 3 of the 6 in use and the two poles paralleled for redundancy. The wiring is like the attached. If you can find the manufacturer's data sheet that will clear things up, or you can use your DMM to discover which terminals are which. I believe that the two terminals that are 180 degrees apart and not in line with the spacing of the others are the commons, which you tie together and run to the speaker jack.
Nice thanks Martin. Maybe I do have it right so why the 6 position switch? There must be other options. Is this KF style or just a normal switch? My other production line amps give only three turns for this switch selection. I noticed there is a small washer on the stackpole with a long lead going into the switch. Can I postion that differently to change the switch at all?
Amplified Nation
www.amplifiednation.com
@ampnation
User avatar
martin manning
Posts: 14308
Joined: Sun Jul 06, 2008 12:43 am
Location: 39°06' N 84°30' W

Re: Help wiring impedence selector

Post by martin manning »

I don't know that particular switch, but I have seen models that use a movable stop of some kind to choose operation with any number of positions up to the maximum. No need for all those extra part numbers.
User avatar
M Fowler
Posts: 14036
Joined: Wed Jan 16, 2008 2:19 am
Location: Walcott ND

Re: Help wiring impedence selector

Post by M Fowler »

It is wired as doubled incase one side of the switch fails the other side is there to save your ass.
amplifiednation
Posts: 2091
Joined: Sun Dec 26, 2010 6:19 pm
Location: Boston
Contact:

Re: Help wiring impedence selector

Post by amplifiednation »

finally understand this. thank you guys...again!!
Amplified Nation
www.amplifiednation.com
@ampnation
amplifiednation
Posts: 2091
Joined: Sun Dec 26, 2010 6:19 pm
Location: Boston
Contact:

done

Post by amplifiednation »

Is there a way to test this? Measure impedance out of the speaker jacks? I tried but wasn't getting consistant readings.
You do not have the required permissions to view the files attached to this post.
Amplified Nation
www.amplifiednation.com
@ampnation
User avatar
M Fowler
Posts: 14036
Joined: Wed Jan 16, 2008 2:19 am
Location: Walcott ND

Re: Help wiring impedence selector

Post by M Fowler »

Right now your going to just get continuity because it is all tied to the OT.

Just make sure the switch is solder well and not touching parts it shouldn't.

They don't give you much room to work with on those switches.
amplifiednation
Posts: 2091
Joined: Sun Dec 26, 2010 6:19 pm
Location: Boston
Contact:

Re: Help wiring impedence selector

Post by amplifiednation »

the switch would have been much easier without the jumpers. once i was done, i had to shorten the jumpers because i was worried there would be interfernence from the heaters on the terminal strip right behind the switch. i think i've got enough clearance now though. i think next time I'll go with a simpler switch...or maybe no switch at all muhahah
Amplified Nation
www.amplifiednation.com
@ampnation
User avatar
angelodp
Posts: 2157
Joined: Tue Jan 15, 2008 2:45 am
Location: L.A.

wire

Post by angelodp »

You can also use teflon wire which has a smaller overall diameter.