Why did Had ground the filaments with 120 r resistors. The ceriatone layout don`t show any resistors on the filaments.
User avatar
David Root
Posts: 3540
Joined: Fri Aug 04, 2006 3:00 pm
Location: Chilliwack BC

Re: Filament grounding

Post by David Root »

Does the Ceriatone power transformer have a center tap on the heater winding that is grounded to the chassis? If it does that is doing essentially the same thing.
Frankie
Posts: 106
Joined: Mon Jun 08, 2009 12:54 am

Re: Filament grounding

Post by Frankie »

David Root wrote:Does the Ceriatone power transformer have a center tap on the heater winding that is grounded to the chassis? If it does that is doing essentially the same thing.
Yes it has a center tap to ground. but I`m not building a ceriatone, just looking at the layout, and on the hammond PT I use(290FEX), I´m not sure if there are center tap. Do I need to use those resistors to ground if I don`t have a center tap?
User avatar
Structo
Posts: 15446
Joined: Wed Oct 17, 2007 1:01 am
Location: Oregon

Re: Filament grounding

Post by Structo »

You need to be clear about which amp you are referring to.

There isn't just one Dumble amp. :wink:
Tom

Don't let that smoke out!
Frankie
Posts: 106
Joined: Mon Jun 08, 2009 12:54 am

Re: Filament grounding

Post by Frankie »

Structo wrote:You need to be clear about which amp you are referring to.

There isn't just one Dumble amp. :wink:
I`m building a ODS, 100w, el 34, non hrm, Hammond Twin, dual showman PT, hammond Marshall OT. Pretty much a #0124 on the preamp side. skyliner tonestack.
User avatar
Deric
Posts: 775
Joined: Sun Jan 14, 2007 2:56 am

Re: Filament grounding

Post by Deric »

According to Hammond's web-site there is no heater center tap on the 290FEX transformer.

http://www.hammondmfg.com/pdf/EDB291FEX.pdf
Deric®
Frankie
Posts: 106
Joined: Mon Jun 08, 2009 12:54 am

Re: Filament grounding

Post by Frankie »

Deric wrote:According to Hammond's web-site there is no heater center tap on the 290FEX transformer.

http://www.hammondmfg.com/pdf/EDB291FEX.pdf
Thanks!
Anyone who knows what the org wire are for. I did ground that one. Is that correct!
User avatar
Deric
Posts: 775
Joined: Sun Jan 14, 2007 2:56 am

Re: Filament grounding

Post by Deric »

The orange is a shield. It should be grounded.
Deric®
Frankie
Posts: 106
Joined: Mon Jun 08, 2009 12:54 am

Re: Filament grounding

Post by Frankie »

Deric wrote:The orange is a shield. It should be grounded.
Thanks again! :)

Frank.
Frankie
Posts: 106
Joined: Mon Jun 08, 2009 12:54 am

Re: Filament grounding

Post by Frankie »

Deric wrote:The orange is a shield. It should be grounded.
Thanks again! :)

Frank.