why do i get more B+ voltage.....

General discussion area for tube amps.

Moderators: pompeiisneaks, Colossal

Post Reply
iknowjohnny
Posts: 1070
Joined: Thu Apr 24, 2008 2:10 am
Location: los angeles

why do i get more B+ voltage.....

Post by iknowjohnny »

....with a 180R sag resistor after the rectifier than without it? I would expect the resistor to drop the B+, and i seem to recall that when i tried this a while back. but now i'm getting 350v without the resistor and 400v with. can someone tell me why this is?
Zippy
Posts: 2052
Joined: Tue Apr 25, 2006 11:18 pm

Re: why do i get more B+ voltage.....

Post by Zippy »

You're right, I'd expect voltage to drop as well.

Did you put it in backwards? :twisted:
User avatar
Structo
Posts: 15446
Joined: Wed Oct 17, 2007 1:01 am
Location: Oregon

Re: why do i get more B+ voltage.....

Post by Structo »

How are you measuring the voltage?

Does the rectifier have a load on it?
Tom

Don't let that smoke out!
iknowjohnny
Posts: 1070
Joined: Thu Apr 24, 2008 2:10 am
Location: los angeles

Re: why do i get more B+ voltage.....

Post by iknowjohnny »

Sorry....i didn't mean that i was measuring B+ when i typed those voltages, but i was measuring plate voltage. But if i measure the B+ at the first can right after the rectifier the voltages are higher but still the resistor yields the high voltage. I think measuring there was resistor in=430v, resistor out=375v.

I have started it down for long periods, but the wiring is so simple i cannot see what i could have done wrong. It's like this....

rectifier output goes to common (center) of a DPDT switch.

one side of the switch goes to the R and the other side of the R goes to the first cap can.

The other side of the switch goes to the cap can.

Now i know what you are thinking, but i checked the switch with my meter on continuity on the unused side of the DPDT switch shows the center is indeed common, plus i checked and re-checked many times to insure the center was connecting to the wire that goes to the input side of the R when the switch is in the position i labeled "sag". I keep thinking i must be spacing, but i don't know how many more times i can check it before i think i'm ready to be institutionalized !
iknowjohnny
Posts: 1070
Joined: Thu Apr 24, 2008 2:10 am
Location: los angeles

Re: why do i get more B+ voltage.....

Post by iknowjohnny »

Man, my face is red ! :oops: I don't know how i mangaed this, but i somehow did indeed space when i metered the switch....the position labeled sag is on the wrong side of the toggle ! Go ahead....i deserve it. :D
Jana
Posts: 1314
Joined: Sun Sep 07, 2008 10:40 pm
Location: Minnesota

Re: why do i get more B+ voltage.....

Post by Jana »

Go ahead....i deserve it.


Okay.

Good Job Homer!

At least the switch wasn't for "Condition Normal" and "Self-Destruct."
iknowjohnny
Posts: 1070
Joined: Thu Apr 24, 2008 2:10 am
Location: los angeles

Re: why do i get more B+ voltage.....

Post by iknowjohnny »

:D Doh !
Jana
Posts: 1314
Joined: Sun Sep 07, 2008 10:40 pm
Location: Minnesota

Re: why do i get more B+ voltage.....

Post by Jana »

I just have to ask, 50 volts drop across a 180R resistor is 277ma current. subtract about 10ma for screens and maybe 7 ma for ax7's and that leaves roughly 260ma for a pair of EL34's. Right? Is anything glowing really bright red or getting really hot? Just wondering.
iknowjohnny
Posts: 1070
Joined: Thu Apr 24, 2008 2:10 am
Location: los angeles

Re: why do i get more B+ voltage.....

Post by iknowjohnny »

No, but i didn't realize this would happen. So when i use a resistor there it raises the current in the power tubes? If so, what size R do you suggest? my PT is 250ma by the way, and the amp has SS rectifier and is a cathode biased pair of el34's.

EDIT: while the difference in voltage at the tubes is a lot more between the resistor in or out of circuit, i just measured across the resistor and got 22v.
User avatar
Structo
Posts: 15446
Joined: Wed Oct 17, 2007 1:01 am
Location: Oregon

Re: why do i get more B+ voltage.....

Post by Structo »

So the resistor is dropping 22v. :D
Tom

Don't let that smoke out!
iknowjohnny
Posts: 1070
Joined: Thu Apr 24, 2008 2:10 am
Location: los angeles

Re: why do i get more B+ voltage.....

Post by iknowjohnny »

Can someone explain the math to me and exactly what Jana meant? I'm not even sure what he meant. Was he saying that he did the math and came to the conclusion my amp is drawing 277ma from the PT? Wouldn't my PT go into meltdown since it is a 250ma PT? It doesn't seem to get hot at all. I'd just like some clarification if someone could help me.
User avatar
stoo
Posts: 156
Joined: Thu May 25, 2006 3:46 pm

Re: why do i get more B+ voltage.....

Post by stoo »

iknowjohnny wrote:Can someone explain the math to me and exactly what Jana meant? I'm not even sure what he meant. Was he saying that he did the math and came to the conclusion my amp is drawing 277ma from the PT? Wouldn't my PT go into meltdown since it is a 250ma PT? It doesn't seem to get hot at all. I'd just like some clarification if someone could help me.