I want to fuse my PT secondaries. Help.

General discussion area for tube amps.

Moderators: pompeiisneaks, Colossal

Post Reply
User avatar
leadfootdriver
Posts: 424
Joined: Tue Mar 08, 2011 10:32 pm

I want to fuse my PT secondaries. Help.

Post by leadfootdriver »

The Express PT is putting out around 300ma's. Does that mean each leg of the secondary puts out around 150ms'a?
passfan
Posts: 1353
Joined: Sun Jan 10, 2010 2:01 pm
Location: Central Florida

Re: I want to fuse my PT secondaries. Help.

Post by passfan »

Customarily , fusing of the B+ occurs after rectification making your question moot.
"It Happens"
Forrest Gump
User avatar
Phil_S
Posts: 6048
Joined: Tue Oct 23, 2007 10:12 pm
Location: Baltimore, MD

Re: I want to fuse my PT secondaries. Help.

Post by Phil_S »

Fast blow 500mA on the CT is what you'll find in Marshall designs. Remember, if you start pulling current through the CT, it means you've got a serious problem and you want it to blow right away. As long as everything is running normally, that 500mA fuse should last forever. It's a reasonable safety measure, but don't over think it.
User avatar
leadfootdriver
Posts: 424
Joined: Tue Mar 08, 2011 10:32 pm

Re: I want to fuse my PT secondaries. Help.

Post by leadfootdriver »

The safer method as per the Wizard is to fuse the PT secondaries. If a rectifier fails, you'll toast the PT.
User avatar
Cygnus X1
Posts: 915
Joined: Tue Apr 22, 2008 5:56 am
Location: Midlands South Carolina

Re: I want to fuse my PT secondaries. Help.

Post by Cygnus X1 »

leadfootdriver wrote:The safer method as per the Wizard is to fuse the PT secondaries. If a rectifier fails, you'll toast the PT.
Not always.
I've seen many instances where diode rectifiers go open, and the main fuse goes...without harming the power transformer.

Fuse location depends on what you are trying to protect.
When I use a secondary fuse it goes on the positive leg after the rectifier to keep downstream caps from blowing up.
That is...if the filters are pulling too much current, then the HT fuse opens.

But I'm really interested in seeing all sides of the argument here, my mind could be changed easily!
tubeswell
Posts: 2337
Joined: Thu Mar 27, 2008 6:42 am
Location: Wellington. NZ

Re: I want to fuse my PT secondaries. Help.

Post by tubeswell »

leadfootdriver wrote:The safer method as per the Wizard is to fuse the PT secondaries. If a rectifier fails, you'll toast the PT.
You can always put a couple of 1000V 1A diodes in series between the HT winding and the rectifier tube anodes (1 x SS diode on each side of the winding). This rectifies the signal on the HT winding (before it gets to the tube rectifier) so that if the tube rectifier fails, it won't dump high VAC onto the filter caps (which would otherwise cause them to short). The voltage drop as per the tube rectifier will still have effect (as will sag etc) because each SS diode's forward voltage drop is only 0.6V (compared to 20V or more from the tube rectifier). Then you can get away with just having the Marshallesque HT fuse (and this will take up less real estate than multiple fuses)
Last edited by tubeswell on Fri Jan 06, 2012 9:41 pm, edited 1 time in total.
He who dies with the most tubes... wins
diagrammatiks
Posts: 558
Joined: Sun Mar 27, 2011 12:28 am

Re: I want to fuse my PT secondaries. Help.

Post by diagrammatiks »

ya fuse them both before the rectifier if you want.

I think 500ma should be ok?
User avatar
VacuumVoodoo
Posts: 924
Joined: Fri Feb 17, 2006 6:27 pm
Location: Goteborg, Sweden
Contact:

Re: I want to fuse my PT secondaries. Help.

Post by VacuumVoodoo »

Mains fuse on primary side should protect against overload exceedeing nominal VA rating by ca 10%
Fuses on secondary side (before any rectifiers) should protect the transformer against short circuit load on any winding. Otherwise you may get a short circuit on heater winding which will not blow the mains fuse but will certainly cook the transformer.
A fuse on HV winding after the rectifier and 1st ripple filter cap should blow before any power tube meltdown.
A lot of fuses in total but a cheap prevention of PT melt down and/or fire.
Aleksander Niemand
------------------------
Life's a party but you get invited only once...
affiliation:TUBEWONDER AMPS
Zagray!-review
User avatar
leadfootdriver
Posts: 424
Joined: Tue Mar 08, 2011 10:32 pm

Re: I want to fuse my PT secondaries. Help.

Post by leadfootdriver »

Thanks for the replies!
katopan
Posts: 612
Joined: Mon Aug 22, 2011 10:10 pm
Location: Melb, Australia
Contact:

Re: I want to fuse my PT secondaries. Help.

Post by katopan »

The other issue with fusing secondaries that makes it difficult is you don't know the transformer thermal curves. If this was an industrial application you'd overlay the device curves with the fuse time-current curves and pick the most appropriate. But not knowing squat about the transformer time-current withstand means all of this is guess work with a bit of rule of thumb. You end up putting in the smallest fuse you can which doesn't blow, and hope that if you have a fault it actually protects your PT. Not something you want to test just in case it doesn't work.

Having said all that I always use a secondary HT fuse and have had it save my PT once when I accidentally brushed a probe across the wrong spot during bench testing.
Post Reply