Solid-State Relays for Switching?

Overdrive Special, Steel String Singer, Dumbleland, Odyssey, Winterland, etc. -
Members Only

Moderators: pompeiisneaks, Colossal

Post Reply
tictac
Posts: 617
Joined: Fri Mar 31, 2006 4:42 am

Solid-State Relays for Switching?

Post by tictac »

Just wondering if anyone is using solid-state relays for switching in an ODS circuit instead of mechanical relays. If so device part numbers and schematic would be interesting to see.

My AC Electronics class topic for this week is "Transistors used as switches" so I wondered if anyone was into this kind of thing...

TT
User avatar
ChrisM
Posts: 1169
Joined: Wed Oct 22, 2008 11:12 pm
Location: Toronto, Canada.

Re: Solid-State Relays for Switching?

Post by ChrisM »

I have used transistors along with CMOS to switch mechanical relays before. Guess that's not much help though.

The transistor was a driver/switch.
DonMoose
Posts: 453
Joined: Thu May 29, 2008 10:39 pm

Re: Solid-State Relays for Switching?

Post by DonMoose »

I sorta thought the International Rectifier PVT series might be worth fiddling with ... if they still make them.

Capacitance across the output side in OFF mode was 12pF - at tube impedances that might be enough to fail to turn 'off' enough in either series or shunt mode (tone suck).
User avatar
glasman
Posts: 1446
Joined: Wed Jan 19, 2005 10:37 pm
Location: Afton, MN (St Croix River Valley)
Contact:

Re: Solid-State Relays for Switching?

Post by glasman »

I pondered the idea of using solid state switching a few years ago. One of the problems that you run into is signal level. The "standard" SS relays with a low "on" resistance are limited in signal swing. You can't exceed the supply voltage for the device. The output from the tone recovery amp would blow it out of the water. If you are running low voltages, say +/- 15V, the 5043 analog switch is the nuts. I have worked on a ton of servo systems that use these for switching.

Another option would be to use Perkin Elmer optoisolators. The problem I saw with these is that the off resistance was not that great (<50Meg) and the switching response was kinda funky.
Located in the St Croix River Valley- Afton, MN
About 5 miles south of I-94
aka K0GWA, K0 Glas Werks Amplification

www.glaswerks.com
paulster
Posts: 1299
Joined: Tue Oct 10, 2006 5:08 pm
Location: Los Angeles & London

Re: Solid-State Relays for Switching?

Post by paulster »

glasman wrote:Another option would be to use Perkin Elmer optoisolators. The problem I saw with these is that the off resistance was not that great (<50Meg) and the switching response was kinda funky.
Also, which is a consideration for you, the RoHS status is indeterminate. Mesa continue to use them despite the exemption expiring and Perkin Elmer have ignored my requests for information on the RoHS compliance status of their product.
User avatar
glasman
Posts: 1446
Joined: Wed Jan 19, 2005 10:37 pm
Location: Afton, MN (St Croix River Valley)
Contact:

Re: Solid-State Relays for Switching?

Post by glasman »

paulster wrote:
glasman wrote:Another option would be to use Perkin Elmer optoisolators. The problem I saw with these is that the off resistance was not that great (<50Meg) and the switching response was kinda funky.
Also, which is a consideration for you, the RoHS status is indeterminate. Mesa continue to use them despite the exemption expiring and Perkin Elmer have ignored my requests for information on the RoHS compliance status of their product.
Yes I saw that as well. Never got past the spec sheet with them. It was just one of a few dozen options I looked at when considering non-relay swithcing. In the end I stuck with RoHS complient relays :).
Located in the St Croix River Valley- Afton, MN
About 5 miles south of I-94
aka K0GWA, K0 Glas Werks Amplification

www.glaswerks.com
tictac
Posts: 617
Joined: Fri Mar 31, 2006 4:42 am

Re: Solid-State Relays for Switching?

Post by tictac »

Mechanical Relays keep looking better and better, at least for the ODS type amp design...

TT
Post Reply