I'm trying to restore my 1966 Bandmaster (see "Bandmaster blues topic)
So far I managed to make the normal channel to work again.
(tremolo ticking later)
But I was wondering about how hot this amp is biased.
In my search for knowledge I found this explanation on this site:
http://www.aikenamps.com/Biasing.html
Quote: "The plate current can also be measured by first measuring the resistance across each side of the output transformer primary (it will usually be different on each side) with the power off. Make a note of the resistance on each side, and then, with the amplifier on, measure the DC voltage drop across each side of the output transformer. Divide this number by the previously measured resistance, and you end up with the plate current for the tubes on that side. Again, if there is more than one tube on each side, you must divide the total current by the number of tubes. This method is extremely accurate, and much safer than the shunt current measurement method, because a slip of the probe won't short anything out due to the high resistance of the voltage measurement setting on the meter compared to the very low resistance of the current measurement setting. You can also make a safer measurement by clipping the negative side of the voltmeter on ground, and measuring the center-tap voltage of the output transformer and the voltage at the plate of each output tube. Subtract the plate voltage from the center-tap voltage and you have the voltage drop across each side, and can then use this to calculate the current in each tube, again dividing by the number of tubes on each side." End quote.
So please can you tell me if I done right when you read the following:
Powertubes are 6L6GC (JJ)
Uct (Centertap voltage) = 422V (measured to ground)
Ua1 (Plate tube 1) = 421V (measured to ground)
Ua2 (Plate tube 2) = 421V (measured to ground)
Resistance from:
Plate from tube 1 to centretap of OT = 70,8Ohm
Plate from tube 2 to centretap of OT = 79,6Ohm
Voltage drop measured from plate tube 1 to centretap of OT = 1V
Voltage drop measured from plate tube 2 to centretap of OT = 1,23V
So: U/R=I
For tube 1= 1V/70,8Ohm = 0,0141242 (A? = 14,1mA?)
For tube 1= 1,23V/79,6Ohm = 0,0154522 (A? = 15,4mA?)
Disipation = U x I (right?) (edit: I first wrote U x R and that's not right
So that would be
for tube 1 = 421V x 0,0141242 = 5,946W(?)
for tube 2 = 421V x 0,0154522 = 6,503W(?)
to what I found in the JJ 6L6GC spec (found here: http://www.jj-electronic.com/index.php? ... &Itemid=11) The max disipation = 6,5W (please confirm)
Thank you for checking my thoughts.